Skip to content
RTI

Checklists by equipment

2 lists · 12 items · 16 photos

Base-mounted HVAC pump maintenance checklists

Base-mounted HVAC pump maintenance checklists for the quarterly and annual rounds: 2 free lists, 12 items and 16 photo requirements, each item naming what to look for and the photo that proves it.

Where each walk sits in the schedule

Base-mounted HVAC pump quarterly maintenance checklistquarterly
Every quarter, walked with the rest of the mechanical-room equipment so the pump numbers are read against the gauges on the same visit. Run by: The mechanical tech on the quarterly mechanical-room round.
Base-mounted HVAC pump annual maintenance checklistannual
Once a year during a system shoulder period, when the pump can be locked out long enough to break the coupling and check alignment cold and hot. Run by: The mechanical service crew on the annual, with the pump locked out for the alignment and bearing work.

What most often fails on a base-mounted HVAC pump

  • A mechanical seal weeping a steady drip called 'normal' until it floods the base and rusts the motor feet.
  • Suction and discharge gauges read but never compared, so a clogging strainer starving the pump goes unnoticed until the flow drops off.
  • Bearing noise logged as 'a little loud' visit after visit with no grease added and no temperature ever felt or measured.
  • Coupling alignment 'eyeballed' at install and never re-checked, so a soft foot or thermal growth chews through seals and bearings on a cycle.
  • Grout under the base cracked or the anchor bolts loose, letting the pump walk and throwing alignment off between services.
  • VFD left in a hand or bypass mode after a past troubleshooting call, so the pump runs full speed and the drive's energy and soft-start are doing nothing.

Common questions

Which base-mounted HVAC pump maintenance rounds do these checklists cover?
Base-mounted HVAC pump quarterly maintenance checklist (quarterly): Every quarter, walked with the rest of the mechanical-room equipment so the pump numbers are read against the gauges on the same visit. Base-mounted HVAC pump annual maintenance checklist (annual): Once a year during a system shoulder period, when the pump can be locked out long enough to break the coupling and check alignment cold and hot.
Who runs the base-mounted HVAC pump maintenance round?
The mechanical tech on the quarterly mechanical-room round. The mechanical service crew on the annual, with the pump locked out for the alignment and bearing work.
What most often fails on a base-mounted HVAC pump?
A mechanical seal weeping a steady drip called 'normal' until it floods the base and rusts the motor feet. Suction and discharge gauges read but never compared, so a clogging strainer starving the pump goes unnoticed until the flow drops off. Bearing noise logged as 'a little loud' visit after visit with no grease added and no temperature ever felt or measured. Coupling alignment 'eyeballed' at install and never re-checked, so a soft foot or thermal growth chews through seals and bearings on a cycle.
Can I run these checklists in RTI?
Yes. Start a free RTI workspace and load any of the 2 lists (12 items in total). The Photo Gate holds the submit button until every mandatory item is answered and its photos are attached, and approved inspections roll into a branded turnover package with a tamper-evident audit trail.