Exhaust fan maintenance checklists

Exhaust fan maintenance checklists for the quarterly and annual rounds: 2 free lists, 10 items and 13 photo requirements, each item naming what to look for and the photo that proves it. Work is commonly verified against IMC (mechanical code); the edition in force is the AHJ's call on each project.

Where each walk sits in the schedule

Exhaust fan quarterly maintenance checklistquarterly
Every quarter, walked with the rest of the roof equipment. Fans fail quietly because nobody occupies the roof. Run by: The HVAC or maintenance tech on the quarterly roof and mechanical round.
Exhaust fan annual maintenance checklistannual
Once a year, paired with the roof membrane walk so roof access happens once. Run by: The HVAC service lead on the annual mechanical service.

What most often fails on an exhaust fan

  • Fan running but moving no air because the shutter is stuck closed or the belt is off.
  • Grease or lint buildup at the hood ignored until it becomes a fire or staining problem.
  • Loose set screws and vibration noise reported by tenants long before the round finds them.
  • Grease-laden wheel cleaned around, not off. The imbalance comes back in a month.
  • Curb fasteners and sealant never checked, and the roof leak gets blamed on the roofer.

Verified against

Families only, never clause numbers. Adoption varies by jurisdiction; confirm the edition your authority having jurisdiction enforces before you run a walk against it.

Common questions

Which exhaust fan maintenance rounds do these checklists cover?
Exhaust fan quarterly maintenance checklist (quarterly): Every quarter, walked with the rest of the roof equipment. Fans fail quietly because nobody occupies the roof. Exhaust fan annual maintenance checklist (annual): Once a year, paired with the roof membrane walk so roof access happens once.
Who runs the exhaust fan maintenance round?
The HVAC or maintenance tech on the quarterly roof and mechanical round. The HVAC service lead on the annual mechanical service.
What most often fails on an exhaust fan?
Fan running but moving no air because the shutter is stuck closed or the belt is off. Grease or lint buildup at the hood ignored until it becomes a fire or staining problem. Loose set screws and vibration noise reported by tenants long before the round finds them. Grease-laden wheel cleaned around, not off. The imbalance comes back in a month.
Which standards is exhaust fan work verified against?
IMC (mechanical code), published by the International Code Council. Adoption varies by jurisdiction. Confirm the edition your authority having jurisdiction enforces before you run a walk against it.
Can I run these checklists in RTI?
Yes. Start a free RTI workspace and load any of the 2 lists (10 items in total). The Photo Gate holds the submit button until every mandatory item is answered and its photos are attached, and approved inspections roll into a branded turnover package with a tamper-evident audit trail.