Skip to content
RTI

Checklists by equipment

2 lists · 9 items · 11 photos

Sewage grinder pump maintenance checklists

Sewage grinder pump maintenance checklists for the quarterly and annual rounds: 2 free lists, 9 items and 11 photo requirements, each item naming what to look for and the photo that proves it.

Where each walk sits in the schedule

Sewage grinder pump quarterly maintenance checklistquarterly
Every quarter, since a grinder pump lives in a sealed basin nobody opens until it alarms, and by then a jammed cutter or a stuck float is already backing sewage up. Run by: The plumbing or maintenance tech running the station through a cycle on the quarterly round, watching it start, grind, pump down and stop, and checking the alarm.
Sewage grinder pump annual maintenance checklistannual
Once a year, the pass that pulls the pump to look at the cutter, impeller and seals, which the quarterly cycle-and-listen check can't see inside a sealed basin. Run by: The pump service tech on the annual service, pulling and inspecting the pump, cleaning the basin and floats, and rechecking the full cycle.

What most often fails on a sewage grinder pump

  • Floats or the level sensor fouled with grease and rag, so the pump either short-cycles or never starts and the basin creeps toward overflow.
  • Check valve stuck open or fouled, so each pump-down drains back into the basin and the pump runs far more than it should.
  • High-level alarm float or the alarm itself dead, so the one warning the station gives before it overflows never sounds.
  • Basin pumped down but never cleaned, so grease and grit build back onto the floats within weeks and the short-cycling returns.
  • Cutter and impeller wear noted but not measured against the manufacturer's limits, so a pump grinding to failure is signed off as serviceable.

Common questions

Which sewage grinder pump maintenance rounds do these checklists cover?
Sewage grinder pump quarterly maintenance checklist (quarterly): Every quarter, since a grinder pump lives in a sealed basin nobody opens until it alarms, and by then a jammed cutter or a stuck float is already backing sewage up. Sewage grinder pump annual maintenance checklist (annual): Once a year, the pass that pulls the pump to look at the cutter, impeller and seals, which the quarterly cycle-and-listen check can't see inside a sealed basin.
Who runs the sewage grinder pump maintenance round?
The plumbing or maintenance tech running the station through a cycle on the quarterly round, watching it start, grind, pump down and stop, and checking the alarm. The pump service tech on the annual service, pulling and inspecting the pump, cleaning the basin and floats, and rechecking the full cycle.
What most often fails on a sewage grinder pump?
Floats or the level sensor fouled with grease and rag, so the pump either short-cycles or never starts and the basin creeps toward overflow. Check valve stuck open or fouled, so each pump-down drains back into the basin and the pump runs far more than it should. High-level alarm float or the alarm itself dead, so the one warning the station gives before it overflows never sounds. Basin pumped down but never cleaned, so grease and grit build back onto the floats within weeks and the short-cycling returns.
Can I run these checklists in RTI?
Yes. Start a free RTI workspace and load any of the 2 lists (9 items in total). The Photo Gate holds the submit button until every mandatory item is answered and its photos are attached, and approved inspections roll into a branded turnover package with a tamper-evident audit trail.