Skip to content

Free checklist

Roof inspection checklist

Roofs fail at the details — the penetrations, the transitions and the terminations — long before the field of the roof gives up. This checklist walks the assembly in the order it goes together, so the photo that matters is taken while the layer underneath is still visible.

Items
11
Photos required
19

Who runs it

Roofing foreman on their own work, or the GC's superintendent before the roof is accepted and covered.

When in the schedule

Twice: once at dry-in, before the finish layer covers the underlayment and flashing, and again at completion before the deck is loaded with equipment.

The checklist

Every item, and the photo that proves it

The photo count on each row is what RTI would require before the item can be submitted. Copy the list as-is, or load it into RTI and let the gate enforce it.

01

Deck and substrate

  • Deck dry, sound and swept before cover

    No standing water, no soft or delaminated sheathing, no fasteners standing proud, no debris under the membrane line.

    2 photos
  • Fastening pattern matches the approved layout

    Spacing at field, perimeter and corner zones; no overdriven or missed fasteners.

    1 photo
  • Slope and crickets built as designed

    Water is directed to drains or scuppers, with crickets behind every curb wider than the drainage path.

    1 photo
02

Underlayment and flashing

  • Underlayment lapped in the direction of drainage

    Laps shingle-style downslope, side laps staggered, no reverse laps at valleys.

    2 photos
  • Base and counter flashing at every vertical

    Flashing carried up the wall, counter-flashed or reglet-set, terminated and sealed.

    2 photos
  • Valley and transition details complete

    Continuous metal or membrane through the valley, no butt joints left open.

    1 photo
03

Penetrations and edge

  • Every penetration flashed and sealed

    One photo per pipe, curb, vent and conduit — boot seated, clamped and sealed at the top.

    3 photos
  • Equipment curbs sealed and level

    Curb flashed above the finished roof line, unit set level, condensate routed off the roof.

    2 photos
  • Edge metal, drip edge and terminations secured

    Continuous cleat or fastening at the required spacing, laps sealed, no oil-canning at corners.

    2 photos
04

Drainage and closeout

  • Drains, scuppers and gutters clear and flowing

    Strainers in place, no debris, water leaves the roof at every low point.

    2 photos
  • Roof clear of debris and staged material

    Fasteners, offcuts and packaging removed; nothing left to puncture the membrane.

    1 photo

What usually sends this back

The failures are almost always the evidence, not the work

  • Flashing photographed after the finish layer went on, so nobody can see how it was lapped.
  • Penetration boots counted but not photographed individually.
  • Positive drainage claimed with no shot of standing water — or of the absence of it — after a wet test.

Run it with the Photo Gate

A checklist nobody can submit half-finished

Load this list into RTI, stick a QR tag on the area it covers, and the submit button stays locked until every mandatory item is answered and the 19 required photos exist. Approved walks roll into a branded turnover package with a tamper-evident record behind every line.

Submission state

Mandatory items answered11 of 11
Photos attached16 of 19
Submit locked — 3 photos missing

The gate is enforced on the server, so it holds even if the phone is offline when the walk happens.