National Fire Protection Association

NFPA 99

NFPA 99 covers the systems a health care facility depends on to keep patients safe: piped medical gases and vacuum, the electrical systems in patient-care spaces, and the risk categories that decide how far each provision reaches. The piping itself is proven by a certified verifier; on a walk the field role is to observe and document that the work matches what that verification will check.

Adoption varies by jurisdiction. Confirm the edition your authority having jurisdiction enforces before you run a walk against it.

What it covers

  • Piped medical gas and vacuum systems
  • Electrical systems in patient-care spaces
  • Risk-category assignment for spaces and systems
  • Zone valves, alarms and outlet identification
  • Support systems serving patient care

What the evidence looks like

  • Zone valve boxes photographed labeled for the rooms they serve, before the ceiling closes.
  • Medical gas outlets shown identified by gas, with the label readable in frame.
  • Area and master alarm panels documented in place, positions and legends shown.
  • Patient-care receptacles photographed at rough-in for the trades that follow.
  • Verification-scope items observed and documented; the certified verifier proves the piping.

Common questions

What is NFPA 99?
Health Care Facilities Code: medical gas and vacuum, patient-care electrical systems, risk categories. It is published by the National Fire Protection Association. NFPA 99 covers the systems a health care facility depends on to keep patients safe: piped medical gases and vacuum, the electrical systems in patient-care spaces, and the risk categories that decide how far each provision reaches. The piping itself is proven by a certified verifier; on a walk the field role is to observe and document that the work matches what that verification will check.
What does NFPA 99 cover?
Piped medical gas and vacuum systems; Electrical systems in patient-care spaces; Risk-category assignment for spaces and systems; Zone valves, alarms and outlet identification; Support systems serving patient care.
What does a field inspection against NFPA 99 look at?
Zone valve boxes photographed labeled for the rooms they serve, before the ceiling closes. Medical gas outlets shown identified by gas, with the label readable in frame. Area and master alarm panels documented in place, positions and legends shown. Patient-care receptacles photographed at rough-in for the trades that follow. Verification-scope items observed and documented; the certified verifier proves the piping.
Which edition of NFPA 99 applies to my project?
Adoption varies by jurisdiction. Confirm the edition your authority having jurisdiction enforces before you run a walk against it.
Which checklists verify work against NFPA 99?
4 free checklists in the RTI library reference this family. Each is listed on this page with the photo evidence every item needs before it can be submitted.

A standard is only met if the evidence exists

RTI holds the submit button until every mandatory item is answered and the photos are attached, then chains the record so it can be proven untouched later.