Signage inspection checklists for the rough-in, final and punch walks: 3 free lists, 10 items and 17 photo requirements, each item naming what to look for and the photo that proves it.

Where each walk sits in the schedule

Signage rough-in inspection checklistrough-in
Before drywall, veneer or the monument base closes over the sign locations, so backing and conduit stubs land where the sign actually mounts. Run by: The sign installer's field lead coordinating with the framer and electrician, or the GC's superintendent releasing walls to close in.
Signage final inspection checklistfinal
After signs are installed and connected, before turnover and before any accessibility review of the finished space. Run by: The GC's superintendent with the sign installer, walking installed locations before the owner's walk.
Signage punch checklistpunch
During closeout, after other trades have finished around the signs and any handling damage or dead lamps have shown up. Run by: The sign installer on a callback, or the GC's superintendent closing signage punch items.

What most often sends signage work back

  • Blocking set to a generic height instead of the sign's own anchor layout, so the fasteners miss the backing once the sign arrives.
  • Power for an illuminated or monument sign roughed to the wrong point, forcing a surface conduit or a wall cut after finishes.
  • Wall closed in before the substrate and anchor points were confirmed against the approved sign shop drawings.
  • Signs hung by eye, so a row of room signs steps up and down or a monument sits out of level against the base.
  • Illuminated sign turned over with dark segments or one face out because the connections were never proven under power.
  • Tactile and braille room signs mounted at the wrong height or on the swing side of the door, missing the accessible requirements.
  • A sign knocked out of line or off level by work around it after installation, left crooked because no one rechecked the row.
  • A dead lamp or LED segment in an illuminated sign missed because the sign was only ever checked in daylight, never powered at the walk.

Common questions

Which signage inspections do these checklists cover?
Signage rough-in inspection checklist (rough-in): Before drywall, veneer or the monument base closes over the sign locations, so backing and conduit stubs land where the sign actually mounts. Signage final inspection checklist (final): After signs are installed and connected, before turnover and before any accessibility review of the finished space. Signage punch checklist (punch): During closeout, after other trades have finished around the signs and any handling damage or dead lamps have shown up.
Who runs a signage inspection?
The sign installer's field lead coordinating with the framer and electrician, or the GC's superintendent releasing walls to close in. The GC's superintendent with the sign installer, walking installed locations before the owner's walk. The sign installer on a callback, or the GC's superintendent closing signage punch items.
What most often sends signage work back?
Blocking set to a generic height instead of the sign's own anchor layout, so the fasteners miss the backing once the sign arrives. Power for an illuminated or monument sign roughed to the wrong point, forcing a surface conduit or a wall cut after finishes. Wall closed in before the substrate and anchor points were confirmed against the approved sign shop drawings. Signs hung by eye, so a row of room signs steps up and down or a monument sits out of level against the base.
Can I run these checklists in RTI?
Yes. Start a free RTI workspace and load any of the 3 lists (10 items in total). The Photo Gate holds the submit button until every mandatory item is answered and its photos are attached, and approved inspections roll into a branded turnover package with a tamper-evident audit trail.